龍灘水電廠7號(hào)機(jī)組轉(zhuǎn)子磁極移位分析及處理工藝探討
[Abstract]:The load rejection test of No. 7 unit in Longtan Hydropower Plant was carried out after the governor revamping. After the test, it was found that most of the magnetic poles of the rotor of the unit were shifted. This paper briefly analyzes the causes of rotor magnetic pole displacement, formulates the corresponding repair scheme, probes into the related treatment technology, and puts forward some reasonable suggestions for the operation and maintenance of the unit.
【作者單位】: 龍灘水電開(kāi)發(fā)有限公司龍灘水力發(fā)電廠;
【分類(lèi)號(hào)】:TV734
【相似文獻(xiàn)】
相關(guān)期刊論文 前10條
1 劉忠德;萬(wàn)安水電廠發(fā)電機(jī)轉(zhuǎn)子磁極存在的問(wèn)題與處理[J];江西電力;2002年05期
2 何松林;吳瑞清;;廣蓄電廠5號(hào)機(jī)組轉(zhuǎn)子磁極故障分析與更換方案[J];云南水力發(fā)電;2008年04期
3 春洪浩;二灘電站轉(zhuǎn)子磁極絕緣問(wèn)題淺談[J];水電站機(jī)電技術(shù);2000年04期
4 古文新;廣東粵電長(zhǎng)潭發(fā)電公司轉(zhuǎn)子磁極改造[J];水電站機(jī)電技術(shù);2005年02期
5 武斌;許小娟;;黃河沙坡頭水力發(fā)電廠一號(hào)發(fā)電機(jī)組轉(zhuǎn)子磁極燒損原因分析及更換方案[J];水電站機(jī)電技術(shù);2011年06期
6 黃俊鋒;;飛來(lái)峽燈泡貫流式發(fā)電機(jī)轉(zhuǎn)子磁極改造技術(shù)[J];電工技術(shù);2009年07期
7 李開(kāi)順;發(fā)電機(jī)轉(zhuǎn)子磁極溫度過(guò)高分析及處理[J];小水電;2000年02期
8 胡光;關(guān)于轉(zhuǎn)子磁極繞組交流阻抗試驗(yàn)的探討[J];水力發(fā)電;1988年10期
9 蔡慶永;發(fā)電機(jī)轉(zhuǎn)子磁極安裝的問(wèn)題及處理[J];小水電;1999年04期
10 柴方光;程振偉;;50MW水輪發(fā)電機(jī)轉(zhuǎn)子磁極異常情況分析[J];華電技術(shù);2011年02期
相關(guān)會(huì)議論文 前1條
1 何松林;吳瑞清;;廣蓄電廠5號(hào)機(jī)組轉(zhuǎn)子磁極故障分析與更換方案[A];南方十三。▍^(qū)、市)水力發(fā)電學(xué)會(huì)秘書(shū)長(zhǎng)會(huì)議論文集[C];2010年
相關(guān)碩士學(xué)位論文 前1條
1 吳越;大型同步發(fā)電機(jī)氣隙遠(yuǎn)程監(jiān)測(cè)與分析[D];華中科技大學(xué);2015年
,本文編號(hào):2490820
本文鏈接:http://www.lk138.cn/kejilunwen/shuiwenshuili/2490820.html