中国韩国日本在线观看免费,A级尤物一区,日韩精品一二三区无码,欧美日韩少妇色

當前位置:主頁 > 科技論文 > 海洋學論文 >

入海排污口選址適宜性評價與案例研究

發(fā)布時間:2018-01-09 11:20

  本文關鍵詞:入海排污口選址適宜性評價與案例研究 出處:《北京化工大學》2015年碩士論文 論文類型:學位論文


  更多相關文章: 入海排污口選址 污染混合區(qū) 生態(tài)風險 海洋生態(tài)價值 多目標決策 污水處理廠選址


【摘要】:近年來,我國沿海地區(qū)人口不斷聚集,經(jīng)濟高速發(fā)展。排污口數(shù)量逐漸增加、位置設置不合理以及污水的排放失控越來越超過我國海域的納污能力,造成我國大部分近岸海域環(huán)境急劇下降。因此,對入海排污口進行優(yōu)化布局是達到海洋環(huán)境整治,逐步實現(xiàn)海洋功能區(qū)目標的關鍵性措施,具有非常深刻的理論與現(xiàn)實意義。本文通過系統(tǒng)研究我國各典型海域的水文動力、海洋生態(tài)和資源分布特征等,剖析和歸納不同海洋環(huán)境功能區(qū)約定的環(huán)境約束因子,并根據(jù)海洋環(huán)境功能區(qū)劃和國家海洋環(huán)境保護法的相關規(guī)定,提出了排污口選址與排放方案比選原則,從海水納污能力、環(huán)境風險、工程經(jīng)濟等多種角度實現(xiàn)選址最優(yōu)化。其次,在廣泛咨詢與調(diào)研的基礎上,辨析入海排污口選址與排放方案比選的影響要素,以此為指導,構(gòu)建了排污口選址適宜性評價指標體系,分別從水域和陸域兩方面對納污能力和入海排污口工程建設的適宜性進行分析。形成涵蓋1個目標因素、2個一級準則因素、8個二級準則因素、11個具體指標的綜合評價指標體系。并且根據(jù)影響污水處理廠選址要素的分析構(gòu)建了污水處理廠評價指標體系。選取層次分析法(AHP)確定指標權(quán)重,灰色關聯(lián)度模型進行方案優(yōu)劣比選實現(xiàn)多因子的比選決策。最后編制入海排污口選址與排放方案比選技術指南,形成一套指導入海排污口設置的比選原則、思路、程序和技術方法,為管理部門科學設置排污口提供技術與決策支持。另外,本文以福建省石獅市東部海域為案例分析,探究入海排污口選址方法與技術。首先根據(jù)當?shù)睾Q蠊δ軈^(qū)劃和相關法律法規(guī)進行初步篩選,在對預選排污口方案的指標因子值進行計算的基礎上,采用構(gòu)建的多目標決策模型對剩余預選方案進行優(yōu)劣排序,擇選出石獅市海域的最適宜排污口位置。
[Abstract]:In recent years, the population in the coastal areas of our country is gathering continuously, the economy is developing at a high speed, the number of sewage outlets is increasing gradually, the location setting is unreasonable, and the sewage discharge out of control is more and more than the pollution absorption capacity of the sea area of our country. As a result, the environment of most of the coastal waters in our country has declined sharply. Therefore, optimizing the layout of the discharge outlet is the key measure to achieve the marine environmental regulation and gradually realize the goal of the marine functional zone. It is of great theoretical and practical significance. This paper systematically studies hydrodynamics, marine ecology and resource distribution characteristics of typical sea areas in China. This paper analyzes and summarizes the environmental constraint factors agreed in different marine environment functional zones, and puts forward the principle of selecting the location of sewage outlet and the selection of discharge schemes according to the relevant regulations of marine environmental functional zoning and national marine environment protection law. The optimization of site selection is realized from the aspects of seawater pollution capacity, environmental risk, engineering economy and so on. Secondly, on the basis of extensive consultation and investigation, the factors affecting the selection of site selection and discharge scheme of sewage outlet into the sea are analyzed. Under the guidance of this, the evaluation index system of site suitability of sewage outlet was constructed, and the capacity of receiving pollution and the suitability of construction of sewage outlet project were analyzed from two aspects of water area and land area, respectively, and a target factor was formed. Two first-level criterion factors and eight second-level criterion factors. According to the analysis of the factors affecting the site selection of the sewage treatment plant, the evaluation index system of the sewage treatment plant was constructed, and the weight of the index was determined by selecting the analytic hierarchy process (AHP). Grey relational degree model is used to compare the advantages and disadvantages of the schemes to realize the multi-factor selection decision. Finally, a set of comparative selection principles to guide the setting of the sewage outlet into the sea is formed by compiling the technical guide for the selection of the location of the sewage outlet and the selection of the discharge scheme. Train of thought, procedure and technical method, provide technical and decision support for management department to set up sewage outlet scientifically. In addition, this paper takes the eastern sea area of Shishi city in Fujian Province as a case study. First, according to the local marine functional zoning and related laws and regulations to carry out preliminary screening, on the basis of pre-selected sewage outlet project index factor value calculation. The multiobjective decision model was used to rank the residual pre-selection scheme and the optimal location of the sewage outlet in Shishi City was selected.
【學位授予單位】:北京化工大學
【學位級別】:碩士
【學位授予年份】:2015
【分類號】:X55;X703

【參考文獻】

相關期刊論文 前4條

1 張永良,趙章元,周岳溪,李玉梁,韓保新;污水海洋處置綜合研究[J];環(huán)境科學研究;1997年01期

2 趙章元,張永良,章燕;我國區(qū)域性污水海洋處置度分區(qū)規(guī)劃研究[J];海洋環(huán)境科學;1997年03期

3 劉鴻志;國外城市污水處理廠的建設及運行管理[J];世界環(huán)境;2000年01期

4 陳尚;任大川;夏濤;李京梅;杜國英;王棟;王其翔;柯淑云;王麗;王敏;趙志遠;;海洋生態(tài)資本價值結(jié)構(gòu)要素與評估指標體系[J];生態(tài)學報;2010年23期

,